Washignton School  District


                MDF,IDF,DTP, Cable Summary

 

Acacia

Sunset

Mountain Sky

R.E. Miller

Royal Palm

Desert View

Sunny Slope

Total  of  7 schools

32-schools,  ( Y )

MDF 

29-DTP +Admin

38-DTP +Admin

20-DTP + Admin

8-DTP +Admin

0 -DTP +Admin

5-DTP +Admin

6-DTP +Admin

Total 32

147 IDF

IDF-1

18-DTP

8-DTP

5-DTP

4-DTP

3-DTP

2-DTP

4-DTP

7 IDF

--

IDF-2

 ---

 ---

8-DTP

5-DTP

6-DTP

4-DTP

5-DTP

5 IDF

--

IDF-3

 ---

 ---

13-DTP

6-DTP

6-DTP

5-DTP

5-DTP

5 IDF

--

IDF-4

 ---

 ---

--- 

13-DTP

8-DTP

6-DTP

7-DTP

4 IDF

--

IDF-5

 ---

 ---

 ---

16-DTP

10-DTP

8-DTP

7-DTP

4 IDF

--

IDF-6

 ---

 ---

 ---

 ---

10-DTP

9-DTP

7-DTP

3 IDF

--

IDF-7

 ---

 ---

 ---

 ---

11-DTP

11-DTP

12-DTP

3 IDF

--

IDF-8

 ---

--- 

 ---

--- 

17-DTP

--- 

 ---

1 IDF

-- 

Total DTP

47

46

46

52

71

50

53

365

1669

Total Nodes

1175

1150

1150 

1300

1775

1250

1325

9125

1304

  • All  data termination Points(DTP)  from the IDF are located withim a reach of  90 meters of  Horizontal Run(30ft)
  • The IDF from the MDF are located withim a reach of 1300ft or 400 meters of Vertical Cable (maximum length for a Multimode-fiber 62.5u)
  • To find the  total of 32 sites base of 7 sites, it is found by the following formula: Y= (Total*32) / 7           

 

Acacia

Sunset

Mountain Sky

R.E. Miller

Royal Palm

Desert View

Sunny Slope

Total  of  7 schools

 

IDF-1                 (1  Fiber  cable)

250ft

300ft

300ft

600ft

  310ft

  765ft

690ft

--

--

IDF-2                (1 Fiber cable)

--

--

150ft

455ft

  430ft

1,100ft

555ft

--

--

IDF-3                 (1 Fiber cable)

--

--

400ft

755ft

  790ft

  300ft

560ft

--

--

IDF-4                (1 Fiber cable)

---

---

---

315ft

1,290ft

  435ft

210ft

--

--

IDF-5                (1 Fiber cable)

---

---

---

340ft

  310ft

  750ft

440ft

--

--

IDF-6                (1 Fiber cable)

--

---

---

---

  190ft

  510ft

530ft

--

--

IDF-7                (1 Fiber cable)

---

---

---

---

  880ft

  315ft

575ft

--

--

IDF-8                (1 Fiber cable) 

---

---

---

---

  610ft

---

---

--

--

IDF to DTP  (4cat 5e cable)

6,900ft

6,440ft

12,500ft

14,460ft

34,800ft

 31,280ft

 24,120ft

--

-- 

MDF to DTP  (4cat 5e cable)

15,600ft

27,960ft

11,600ft

1,940ft

  ---

 2,040ft

 3,840ft

--

-- 

DTP to PC's (40ft-node)

47,000ft

46,000ft

46,000ft

52,000ft

71,000ft

 50,000ft

 53,000ft

-- 

--

Total Cat5e

69,500ft

80,400ft

70,100ft

68,400ft

105,800ft

 83,320ft

 80,960ft

 558,480ft

 2,553,052ft

Total Fiber       (1 cable-IDF)   

250ft   

300ft 

850ft

2,465ft

4,810ft

4,175ft

3,560ft

16,410ft,

75,017ft

 

CISCO   Equipment          

Acacia

Sunset

Mountain Sky

R.E. Miller

Royal Palm

Desert View

Sunny Slope

Total  of  7 schools

32-schools,  ( Y )

MDF- 6509

2

2

2

2

2

2

2

14

64

IDF -C2948G

1

1

5

8

7

7

32

147

IDF GBIC for C2948G fiber

2 2 6 10 16 14 14 64 293

DTP -C1924-EN

47

46

46

52

71

50

53

365

1669

WAN-2620  1  7  32
                   
  • The DTP to PCS's cat 5e is calculated, estimating the room distance (40ft) and multiplying times the number of nodes to be wires
  • The IDF to DTP or MDF to DTP is calculated by estimating  a catchment distance to each DTP from the MDF or IDF and multiplying per 4 runs. If cables are run through conduit, then the cable is the distance of the conduit to the n DTP